JBW-150/300/500/750H Microcomputer Controlled Metal Pendulum Impact Testing Machine
|
Model |
JBW-300H |
JBW-500H |
|
Maximum impact energy |
300J |
500J |
|
Effective scope of application |
30-240J(20%-80%FS) |
50J-400J(20%-80%FS) |
|
Optional pendulum |
150J/300J |
250J/500J |
|
Pendulum advance angle |
150° |
150° |
|
The distance from the axis of the pendulum shaft to the center of the strike |
750mm |
800mm |
|
Pendulum moment |
M300=160.7696N.m M150=80.3848N.m |
M=267.9492N.m M=133.9746N.m |
|
Impact velocity |
5m/s |
5.2m/s |
|
Anvil span |
40mm |
40mm |
|
Anvil fillet radius |
R1-1.5mm |
R1-1.5mm |
|
Anvil inclination angle |
11°±1° |
11°±1° |
|
Impact edge angle |
30°±1° |
30°±1° |
|
R2 Impact Blade |
2mm±0.05mm(Chinese standard) |
2mm±0.05mm(Chinese standard) |
|
R8 Impact Blade |
8mm±0.05mm(American Standard) |
8mm±0.05mm(American Standard) |
|
Impact blade width |
10mm-18mm |
10mm-18mm |
|
Impact knife thickness |
16mm |
16mm |
|
Meet the sample specifications |
10*10*55mm 7.5*10*55mm 5*10*55mm 2.5*10*55mm |
10*10*55mm 7.5*10*55mm 5*10*55mm 2.5*10*55mm |
|
Machine weight |
480Kg |
600Kg |
|
Rated current |
Three-term four-wire 380V 50Hz |
Three-term four-wire 380V 50Hz |
|
Main configuration: 1. Hand control operation box 2. Computer A4 printer 3. Aluminum alloy fully enclosed protective cover Technical indicators remarks: 1. Impact force sensor: range 50KN (100KN), accuracy better than ±1.0% (with amplifier accuracy) 2. AD converter: 16 bits, frequency response 1.25MHz 3. Signal amplifier: frequency response 1.5MHz 4. Rotary encoder: 3600 lines 5. Data acquisition card: imported high-performance data acquisition card, sampling rate ≥1.25M |
||
GB/T3038-2002 "Inspection of Pendulum Impact Tester"
GB/T229-2007 "Metal Charpy Notch Impact Test Method"
JJG145-82 "Pendulum Impact Testing Machine"